Search results for "radiation protection"
showing 10 items of 72 documents
Evaluation of the shielding in a treatment room with an electronic brachytherapy unit.
2017
Esteya® (Elekta Brachytherapy, Veenendaal, The Netherlands) is an electronic brachytherapy (eBT) system based on a 69.5 kVp x-ray source and a set of collimators of 1 to 3 cm in diameter, used for treating non-melanoma skin cancer lesions. This study aims to estimate room shielding requirements for this unit. The non-primary (scattered and leakage) ambient dose equivalent rates were measured with a Berthold LB-133 monitor (Berthold Technologies, Bad Wildbad, Germany). The latter ranges from 17 mSv h-1 at 0.25 m distance from the x-ray source to 0.1 mSv h-1 at 2.5 m. The necessary room shielding was then estimated following US and some European guidelines. The room shielding for all barriers…
Addressing ecological effects of radiation on populations and ecosystems to improve protection of the environment against radiation: Agreed statement…
2016
AbstractThis paper reports the output of a consensus symposium organized by the International Union of Radioecology in November 2015. The symposium gathered an academically diverse group of 30 scientists to consider the still debated ecological impact of radiation on populations and ecosystems. Stimulated by the Chernobyl and Fukushima disasters' accidental contamination of the environment, there is increasing interest in developing environmental radiation protection frameworks. Scientific research conducted in a variety of laboratory and field settings has improved our knowledge of the effects of ionizing radiation on the environment. However, the results from such studies sometimes appear…
Radiation protection in non-ionizing and ionizing body composition assessment procedures
2020
Body composition assessment (BCA) represents a valid instrument to evaluate nutritional status through the quantification of lean and fat tissue, in healthy subjects and sick patients. According to the clinical indication, body composition (BC) can be assessed by different modalities. To better analyze radiation risks for patients involved, BCA procedures can be divided into two main groups: the first based on the use of ionizing radiation (IR), involving dual energy X-ray absorptiometry (DXA) and computed tomography (CT), and others based on non-ionizing radiation (NIR) [magnetic resonance imaging (MRI)]. Ultrasound (US) techniques using mechanical waves represent a separate group. The pur…
MRI-assisted radiation therapy planning of brain tumors--clinical experiences in 17 patients.
1991
A new and simple method for precise determination of lateral opposed treatment portals was developed and used in 17 patients. Compared to CT, MRI led to significant changes of portals in 59% (10/17) of cases. Individual shielding blocks could be precisely designed by use of our new method. MRI is the procedure of choice in local radiation therapy planning of brain tumors.
Reliability and validity of the Digigraph 100 in orthodontic diagnosis.
2001
Cephalometric analyses of lateral cephalograms allow important statements to be made on diagnosis and treatment planning. Such radiographs should, however, be taken with a considerable reduction in radiation exposure. With the Digigraph 100 (Dolphin Imaging Systems Inc., USA) a cephalometric technique based on distance measurements of emitted sonic signals is now available. This study was aimed at determining the degree to which this procedure can cope with the requirements of reliability and validity in the field of orthodontics. For this purpose 50 volunteers were examined by conventional cephalometry with manual tracing of lateral cephalograms as well as by sonic cephalometry, with Jarab…
Adult exposures from MDCT including multiphase studies: first Italian nationwide survey.
2014
To evaluate the radiation dose in routine multidetector computed tomography (MDCT) examinations in Italian population.This was a retrospective multicentre study included 5,668 patients from 65 radiology departments who had undergone common CT protocols: head, chest, abdomen, chest–abdomen–pelvis (CAP), spine and cardiac. Data included patient characteristics, CT parameters, volumetric CT dose index (CTDIvol) and dose length product (DLP) for each CT acquisition phase. Descriptive statistics were calculated, and a multi-regression analysis was used to outline the main factors affecting exposure.The 75th percentiles of CTDIvol (mGy) and DLP (mGy cm) for whole head were 69 mGy and 1,312 mGy cm…
Radiation risks knowledge in resident and fellow in paediatrics: a questionnaire survey
2015
Background: Analyse through a multi-choice anonymous questionnaire the knowledge's level in paediatric residents and fellows in two different main Italian hospital, looking mainly to the information to patients and relatives related to risks of ionizing radiation used in common radiological investigations in children. Methods: 65 multi choice questionnaires were distributed to paediatric residents and fellows of two different hospitals, an University Hospital (A.O.U.P. "P. Giaccone"- University of Palermo) and a national reference centre for paediatrics (Ospedale Pediatrico Bambino Gesù - Rome). The questionnaire included twelve multiple-choice questions with the aim of analyzing the knowle…
CT exposure in adult and paediatric patients: a review of the mechanisms of damage, relative dose and consequent possible risks.
2014
An increase has been observed not only in the absolute number of CT examinations but also in the length of coverage and number of scanning phases, with the result that exposure to ionising radiation from CT is becoming an increasingly serious problem. The extent of the problem is not entirely known and cannot be adequately addressed without proper knowledge of all the phases that leads to the effective dose calculation. In light of the growing awareness of the issue of ionising radiation dose and the possible risk for the individual and the population, there is a need for radiologists, medical physicists and radiographers to play an active role in dose management. In this review, the author…
Fetal dose measurements and shielding efficiency assessment in a custom setup of (192)Ir brachytherapy for a pregnant woman with breast cancer.
2015
To assess the radiation dose to the fetus of a pregnant patient undergoing high-dose-rate (HDR) (192)Ir interstitial breast brachytherapy, and to design a new patient setup and lead shielding technique that minimizes the fetal dose.Radiochromic films were placed between the slices of an anthropomorphic phantom modeling the patient. The pregnant woman was seated in a chair with the breast over a table and inside a leaded box. Dose variation as a function of distance from the implant volume as well as dose homogeneity within a representative slice of the fetal position was evaluated without and with shielding.With shielding, the peripheral dose after a complete treatment ranged from 50 cGy at…
EPI-CT: design, challenges and epidemiological methods of an international study on cancer risk after paediatric and young adult CT
2015
Computed tomography (CT) has great clinical utility and its usage has increased dramatically over the years. Concerns have been raised, however, about health impacts of ionising radiation exposure from CTs, particularly in children, who have a higher risk for some radiation induced diseases. Direct estimation of the health impact of these exposures is needed, but the conduct of epidemiological studies of paediatric CT populations poses a number of challenges which, if not addressed, could invalidate the results. The aim of the present paper is to review the main challenges of a study on the health impact of paediatric CTs and how the protocol of the European collaborative study EPI-CT, coor…